Measurement display MA100/2
Incremental, display accuracy 1 μm
- Display accuracy max. 1 μm
- Repeat accuracy max. ±1 μm
- High-contrast LCD, 12-digit LCD dot matrix
- Incremental measurement and reset function
- Direct reference/offset value input
- Reference input
- Works with sensor MS100/1
- Option: serial interface RS232/RS485/switching output
- Option: TG01 bench housing
Technical drawing
Technical Specifications
Mechanical data
Electrical data
System data
Ambient conditions
Feature
Technical Specifications
Enhancement
Housing design
 built-in housing, plastic
Control panel excerpt 92+0.8 x 45+0.6 IEC 61554
Feature
Technical Specifications
Enhancement
Operating voltage
24 V DC ±20 %
115 V AC ±10 %
230 V AC ±10 %
Current consumption
70
 mA
 at 24 V DC
20
 mA
 at 115 V AC
10
 mA
 at 230 V AC
Display/display range
 12-digit, LCD dot matrix, backlit
-9999999 … 9999999, arithmetic signs, units
Switching outputs
 with or without
2x 30 V ≤100 mA
Interface
 without, RS232, RS485
Type of connection
 connector
9-pole (supply, switching output, interface/reference connection)
 mini-DIN
6-pole, 1x socket (MS100/1 sensor)
Feature
Technical Specifications
Enhancement
Resolution
0.001
 mm
,
0.01
,
0.1
,
1
,
10
programmable angle display
0.001
,
0.01
,
0.1
,
1
 in
System accuracy
±(0.01 + 0.01 x L) mm: L in m
 at TU = 20° C
Repeat accuracy
±0.001
 mm
±1 increment
Travel speed
≤2
 m/s
Feature
Technical Specifications
Enhancement
Ambient temperature
0 … 50 °C
Storage temperature
-20 … 80 °C
Relative humidity
≤95
 %
condensation inadmissible
EMC
 EN 61000-6-2
interference resistance / immission
 EN 61000-6-4
emitted interference / emission
Protection category
 IP40 whole device
EN 60529
 IP60 at the front with switchboard installation
EN 60529
More information
pin assignment
Signal |
PIN |
Reset |
1 |
+24 V DC; ≤50 mA (reference switch) |
2 |
GND |
3 |
nc |
4 |
"RS232 (RXD), RS485 (DÜB), actor A2" |
5 |
RS232 (TXD), RS485 (DÜA), actor A1 |
6 |
PE |
7 |
N (230/115 V AC); GND (24 V DC) |
8 |
L (230/115 V AC); +UB (24 V DC) |
9 |
3 |
2 |
Purchase order
Product configuration
Feature
Select specifications
Enhancement
Select your specifications:
Operating voltage
1
interface/
protocol
XX/XX
switching output
SO
only with XX/XX interface
Accessories
Comparable products
Scope of delivery
- MA100/2
- Installation Instructions