reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumption
typical 40 mA
≤100 mA (no load)
Output signal level high
≥UB - 3.0 V
short-circuit proof
Output signal level low
≤2.5 V
short-circuit proof
Pulse frequency
≤200 kHz
Load
±40 mA
max. adm.
Type of connection
open cable end
1x M12 connector
8-pole, 1x pin
LD5 output circuit
Feature
Technical data
Additional information
Operating voltage
5 V DC
reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumption
typical 40 mA
≤90 mA (no load)
Output signal level high
≥2.5 V
short-circuit proof
Output signal level low
≤0.5 V
short-circuit proof
Pulse frequency
≤300 kHz
Load
±20 mA
max. adm.
Type of connection
open cable end
1x M12 connector
8-pole, 1x pin
LD24 output circuit
Feature
Technical data
Additional information
Operating voltage
8 … 30 V DC
reverse polarity protected, the power-supply unit corresponds to Class 2 (UL 1310)
Current consumption
typical 40 mA
≤90 mA (no load)
Output signal level high
≥2.5 V
short-circuit proof
Output signal level low
≤0.5 V
short-circuit proof
Pulse frequency
≤300 kHz
Load
±20 mA
max. adm.
Type of connection
open cable end
1x M12 connector
8-pole, 1x pin
System data
Feature
Technical data
Additional information
Approval
UL
UL 61010-1, File No. E503367
Characteristics of functional safety
Feature
Technical data
Additional information
MTTFd
63.4 year(s)
Ambient conditions
Feature
Technical data
Additional information
Ambient temperature
-20 … 70 °C
at speed ≤2000 min -1
-20 … 60 °C
at speed ≤2500 min -1
EMC
EN 61000-6-2
interference resistance / immission
EN 61000-6-3
emitted interference / emission
Safety regulations
UL 61010-1
Indoor use, outdoor use possible, not intended for use involving direct exposure to UV light. Environment dry / wet. Protection class III as per EN 61140. Pollution degree 2 as per EN 61010. Maximum humidity 93% at 40 °C.