Magnetic sensor LE100/1
Incremental, analog interface 1 VSS
- Repeat accuracy max. ±1 μm
- LED status display
- Works with MB100/1 magnetic tape
- Works with MBR100 magnetic tape ring
- Reading distance ≤0.4 mm
- Signal period 1000 μm
- Output circuit sin/cos 1 VSS
- Robust metal housing
Technical drawing
Technical Specifications
Mechanical data
Electrical data
System data
Ambient conditions
Feature
Technical Specifications
Enhancement
Housing
 zinc die-cast/aluminum
M design
 zinc die-cast
ZM design
Sensor/band reading distance
0.1 … 0.4 mm
O, IA, ID reference signal
0.1 … 0.2 mm
reference signal RB, RD
Sensor/ring reading distance
0.1 … 0.4 mm
O, IA, ID reference signal
0.1 … 0.2 mm
reference signal RB, RD
Cable sheath
 PUR, suitable for drag-chain use
6, 8-core ø5-0.4 mm
Cable bending radius
 5x cable diameter
static
 7.5x cable diameter
dynamic
Service life of cable
>5
 Million cycles
Under the following test conditions:
Feature
Technical Specifications
Enhancement
Operating voltage
10.5 … 30 V DC
reverse polarity protection
5 V DC ±5 %
no reverse polarity protection
Current consumption
<25
 mA
 at 24 V DC
<50
 mA
 at 5 V DC
Output signals
 sin, /sin, cos, /cos, index, /index
Output voltage
1 VPP ±10 %
 at 0 … 70 °C
120 Ω teminal resistance
Output impedance
0
 Ω
 (Rload >75 Ω)
short-circuit proof
Signal period
1000
 µm
Offset voltage
2.5 V, ±100 mV
sine/cosine mean to GND (10.5 … 30 V DC)
UB/2 ±100 mV
sine/cosine mean to GND (5 V DC)
Phasing
90°±1°, ±3° (20 kHz)
sin/cos
45
 °
 sin/cos
reference signal is symmetric around the positive intersection point of the sin/cos signals (phase 45°)
Real-time requirement
 speed-proportional signal output
Type of connection
 open cable end
 plug connector
7/8-pole
Signal image
E: Reference voltage 2.5 V
F: 1 VSS ±10 %
J: ≥0.2 V
K: ≥0.3 V
L: 100° ±20 %
M: 90° ±1.0° / ±3° (25 kHz)
X: 1 VSS
F: 1 VSS ±10 %
J: ≥0.2 V
K: ≥0.3 V
L: 100° ±20 %
M: 90° ±1.0° / ±3° (25 kHz)
X: 1 VSS
Feature
Technical Specifications
Enhancement
Linearity deviation
±2
 µm
 at TU = 20° C
0.2 mm sensor/strip reading distance
Repeat accuracy
1
 µm
Measuring range
∞
Circumferential speed
≤20
 m/s
sin/cos
Travel speed
≤20
 m/s
sin/cos
Feature
Technical Specifications
Enhancement
Ambient temperature
-10 … 70 °C
Storage temperature
-30 … 80 °C
Relative humidity
100
 %
condensation admissible
EMC
 EN 61000-6-2
interference resistance / immission
 EN 61000-6-4
emitted interference / emission
Protection category
 IP67
EN 60529
Shock resistance
500 m/s2, 11 ms
EN 60068-2-27
Vibration resistance
200 m/s2, 50 Hz … 2 kHz
EN 60068-2-6
More information
pin assignment
without reference signal
Signal |
E1 |
E6X |
GND |
black |
1 |
sin |
red |
2 |
/sin |
orange |
3 |
cos |
yellow |
4 |
/cos |
green |
5 |
+UB |
brown |
6 |
nc |
7 |
with reference signal
Signal |
E1 |
E6X |
sin |
red |
1 |
cos |
yellow |
2 |
index |
blue |
3 |
+UB |
brown |
4 |
GND |
black |
5 |
/sin |
orange |
6 |
/cos |
green |
7 |
/index |
violet |
8 |
Hint for mounting
For systems with reference points on the magnetic tape please take care that sensor and strip are correctly aligned (see picture).
Reference signal |
O, I |
R |
A, Sensor/tape reading distance |
≤0.4 mm |
≤0.2 mm |
B, Lateral offset |
±2 mm |
±0.5 mm |
C, Alignment error |
±3° |
±3° |
D, Longitudinal inclination |
±1° |
±1° |
E, Lateral inclination |
±3° |
±3° |
3 |
2 |
2 |
(Sensor representation symbolic)
(Sensor representation symbolic)
System components
Purchase order
Product configuration
Feature
Select specifications
Enhancement
Select your specifications:
Operating voltage
10
design
M
Type of connection
E1
Cable length
1.0
1.0
20.0 mm, in steps of 1 mm
reference signal
O
index signal every 1 mm
index signal every 1 mm
Accessories
Comparable products
Scope of delivery
- LE100/1
- Fastening set
- Quick Start Guide